Fresh arterial allograft as a replacement for an infected common femoral prosthetic graft and recurrent false aneurysm
PDF

Keywords

Blood vessel prosthesis, infection, allograft

Abstract

Replacing an infected vascular prosthetic conduit with an allograft is a possible solution of this complication given the low recurrence of infection. It is most commonly utilized for cases where the use of autologous tissue is not an option. We present the case of a 70-year-old patient who had undergone repeated vascular reconstructions in the right lower limb. He was admitted to our department due to a progressively growing mass in the right groin and subsequently placed on the waiting list for a fresh allograft. The patient had the infected false aneurysm and prosthetic material of the femoral bifurcation replaced with an arterial allograft. The previous femoral popliteal autovenous bypass graft was reimplanted into the allograft. There were signs of sepsis during the operation; however, the blood culture was negative. Cultures from neither the wound nor the drain revealed the presence of any bacteria. The patient was discharged on the seventh post-operative day with prophylactic antibiotics. An early followup confirmed that there were no signs of recurrent infection and that the reconstruction remained patent. Seven and half months after the surgery, the femoral popliteal bypass graft became occluded and a conservative approach was chosen. A small thrombosed false aneurysm of the graft was revealed two years after the surgery due to transient non-compliance of the patient to immunosuppression therapy. It was treated conservatively. Two and a half years after the surgery, the allograft still remains open and the limb is preserved.

PDF